Date: 2017 - 10 - 27
Executive Standard:IEC60269.6;GB/T13539.6Rated Voltage:DC 1000V DC 1500VRated Current:32A;63ABreaking Capacity:≥10KAProtection Feature:gPVInstallation mode:Standard TH35 rail mountingCharacteristic:Easy to install and replace, small size, novel structure, safe and reliable.Suitable for:Solar photovoltaic system in the bus box, inverter, battery charging control system. PV series cylindrical cap fuse base specificationsTypeRated Voltage(V)Rated Current(A)Dimension  (mm)Outline...
Model: 低压
Date: 2017 - 10 - 27
SIST series fuse base selection specificationsType:Sist□01Rated insulation voltage  Ui(V):690VOutline dimension:Base typeFitted fuse typeDimension (mm)OutlineABCDEHMRT16-00(Sist101)NGTC00/NT00/NH009711520302658M8×16Fig.1RT16-1     (Sist201)NGTC1/NT1/NH117520335503782M10×20Fig.2RT16-2(Sist401)NGTC2/NT2/NH220022435503785M10×25Fig.2RT16-3 (Sist601)NGTC3/NT3/NH321023635503896M12×30Fig.3RT16-4 (Sist1001)NT4/NH4260305459548148M12×30Fig.4...
Model:
Date: 2022 - 11 - 01
1140V fuse base Technical parameter:Type:RS17/1P-1140VNumber of poles:1PRated operating voltage  Ui (V):1140V TypeRated Current(A)OutlineFitted coreRS17-1140-C00-1P base≤160AFig.3RS17-□V/□A-C00RS17-1140-C1-1P base≤250AFig. 4RS17-□V/□A-C1RS17-1140-C2-1P base≤315AFig.5RS17-□V/□A-C1 Base size:Fig.3:RS17-1140-C00-1P baseFig.4:RS17-1140-C1-1P baseFig. 5:RS17-1140-C2-1P baseAnnotation: If there is no note, the base is RS17-1140-C00-...
Model:
Date: 2022 - 11 - 01
1140V fuse guardIntroduction: The main function of the protective cover is the external and internal protection of the fuse, flame retardant and explosion-proof. It can protect the core in the areas with bad working conditions.Rated operating voltage:AC1140VRated withstand voltage:AC1500VClass of protection:IP101500VDC fuse protection coverRated operating voltage:1500VRated withstand voltage:2000VClass of protection:IP102. Supporting load switchProduct introduction:HR6(NB) series isolation ...
Date: 2017 - 10 - 27
Executive Standard:IEC60269Maximum voltage:See below tableMaximum load current:See below tableCharacteristic:Compact structure, easy installation, reliable insulation. It is used with NGT series fuse and hook type (Z type) quick fuse.Square busbar hook type fuse base specifications                                    &#...
5页次1/1HOMEPrev1NextLAST
Copyright © 2005 - 2013 ShaanXi ZhenLi Electric Power Technology Co.,Ltd.
犀牛云提供企业云服务    
   
Sweep the concern our letter
Address:No.2055,Shanglinyuan 5th Road, High-tech district, Xi'an City Shaanxi Province, China 
Tel: 86 029-86795471
Fax: 86 029-86307131
Zip Code:330520
Share to:
X
等待加载动态数据...

等待加载动态数据...

3

SKYPE 设置

4

阿里旺旺设置

5

TEL:

6

二维码管理

展开