Model:
Date: 2022 - 11 - 01
1140V fuse base Technical parameter:Type:RS17/1P-1140VNumber of poles:1PRated operating voltage  Ui (V):1140V TypeRated Current(A)OutlineFitted coreRS17-1140-C00-1P base≤160AFig.3RS17-□V/□A-C00RS17-1140-C1-1P base≤250AFig. 4RS17-□V/□A-C1RS17-1140-C2-1P base≤315AFig.5RS17-□V/□A-C1 Base size:Fig.3:RS17-1140-C00-1P baseFig.4:RS17-1140-C1-1P baseFig. 5:RS17-1140-C2-1P baseAnnotation: If there is no note, the base is RS17-1140-C00-...
Date: 2017 - 10 - 27
Type:RTZ-□-□V/□APerformance coincidence:IEC60269;GB/T31465.6 ;JASO D622;ISO8820Rated voltage:DC 500V,700V,1000VRated current:10A-2000ABreaking capacity:≥100KAProtective characteristic:aRInstallation mode:Bolted connectionCharacteristic:Small size, low power consumption, high breaking ability, time constant T Suitable for: small and medium-sized passenger cars, bus lithium battery pack, inverter, capacitor and charging device short circuit protectionRTZ-50Series fuse specificationsTable 1TypeRate...
Date: 2017 - 10 - 27
RZS-1000 fuse indicator, suitable for AC 50HZ, rated voltage 1000V and below lines, used in L-type busbar fuses and other products.Finger melting is an external fuse indicator, directly connected to the fuse, when the fuse is blown, the finger melting at the same time to promote the micro switch, the contact is closed, and the electrical signal is sent.The fuse indicator is mainly composed of micro switch, finger core, bracket, copper clip and connecting plate. The dimensions are shown in Figure...
Date: 2017 - 10 - 23
This product applies to the indoor AC 50 ~ 60Hz system with the rated voltage of 3.6~7.2kV, and may be used along with Mitsubishi vacuum contactor as short-circuit and overload protection element for the high-voltage motor and transformer.Basic parameters                   ModelRated Voltage  (kV)Rated Current (A)Outline DrawingPurposeφA±1φA±2C±2D±1  CLS 3.6M20,M50,M1...
Date: 2017 - 10 - 23
This product applies to indoor AC 50~60Hz system with the rated voltage of 8.3 ~ 40.5kV for the short-circuit protection of transformer and other power equipment, and is used in series with the oil-immersed transformer overload protection fuse, and can provide the full range protection for indoor power system. The product has passed the type test conducted by the national high-voltage electrical equipment quality supervision and inspection center, and conforms to GB15166.2 and IEC282-1.Mode...
product name: Cut out fuse
Model:
Date: 2017 - 10 - 10
product name: RS17 DC fuse series
Model:
Date: 2024 - 11 - 01
Type:RS17-□VDC/□A-□Rated voltage:750V-1000V DCRated current:50A-1800ABreaking capacity: 50KAProtective characteristic:aREnforce standards:IEC60269.4,GB/T13539.4Characteristic:This product is for DC system protection, and the switch to cooperate with the protection, mainly to meet the short circuit protection of the line. It has low power consumption, high breaking ability, good current limiting characteristics, low arc current, and can be connected with visual indication or switch electrical sig...
Model:
Date: 2022 - 11 - 01
No.TypeRated voltage(V)Rated current(A)Dimension(mm)Outline ABC1RS17-380/□-L250-A69010、20、30、50、63、80、100、150、200、200、315、350557496Fig.29 2RS17-500/□-L250-A8003RS17-800/□-L250-D100010、20、30、50、63、80、100、150、200、200、25072901134RS17-1000/□-L250-E12501RS17-380/□-L11-A38010、20、30、50、63、80、100、150、200、200、315、35012415757Fig.302RS17-500/□-L11-A5003RS17-800/□-L11-D80010、20、30、50、63、80、100、150、200、200、315148181814RS17-1000/□-L11-E1000153186865RS17-1500/□-L11-K150010、20、30、50、63、80、100、150、200、20020...
Model:
Date: 2022 - 11 - 01
1140V fuse guardIntroduction: The main function of the protective cover is the external and internal protection of the fuse, flame retardant and explosion-proof. It can protect the core in the areas with bad working conditions.Rated operating voltage:AC1140VRated withstand voltage:AC1500VClass of protection:IP101500VDC fuse protection coverRated operating voltage:1500VRated withstand voltage:2000VClass of protection:IP102. Supporting load switchProduct introduction:HR6(NB) series isolation ...
Date: 2017 - 10 - 23
This product applies to indoor AC 50~60Hz system with the rated voltage of 15.5kV and shall be used in series with the backup fuse for oil-immersed transformer overload protection, and can provide the full range protection for indoor power system. The product has passed the type test conducted by the national high-voltage electrical equipment quality supervision and inspection center, and conforms to GB15166.2 and IEC282-2.Model: Basic parameters: Product Model Rated Voltage  (kV)...
Model:
Date: 2024 - 09 - 06
Electrical Specifications The fuse is designed to provide full range protection for voltage transformers and monitoring equipment in the new energy tank transformer. It has the characteristics of high breaking capacity and good current limiting characteristics. It is guaranteed to be similar to the RT18 series in dimensions, and has a compact structure to ensure easy installation.Type:  NBR14-□V/□ARated voltage:AC800V, 1000V,1140V Rated current:0.5A-40ABreaking capacity:50KAProtec...
Date: 2017 - 10 - 27
Performance coincidence:IEC60269;GB/T13539.2Rated voltage: AC 500/690V Rated current:6A-1250ABreaking capacity:120KA/500V AC  100KA/690V  ACProtection category:gGInstallation mode:Plug-in typeCharacteristic:Small size, light weight, low power consumption, high breaking ability, safe and reliable.Be suitable for:Short circuit and overload protection of distribution system, wire and cable, motor, factory and mine lines, switchgear and electrical equipment.Type description:NT/RT16 se...
45页次2/4HOMEPrev1234NextLAST
Copyright © 2005 - 2013 ShaanXi ZhenLi Electric Power Technology Co.,Ltd.
犀牛云提供企业云服务    
   
Sweep the concern our letter
Address:No.2055,Shanglinyuan 5th Road, High-tech district, Xi'an City Shaanxi Province, China 
Tel: 86 029-86795471
Fax: 86 029-86307131
Zip Code:330520
Share to:
X
等待加载动态数据...

等待加载动态数据...

3

SKYPE 设置

4

阿里旺旺设置

5

TEL:

6

二维码管理

展开