PRODUCTS  

DC fuse for solar PV system protection

Product description: Type:PV-□-□VDC/□AExecutive Standard:IEC60269.6; GB/T13539.6Rated Voltage:DC 1000V、1500VRated Current:1A-400ABreaking Capacity:See below tableProtection Feature:gPVInstallation mode:Round tube with base; Square tube insert typeCharacteristic:Full range DC breaking fuse, time constant T≤3ms.Suitable for:Solar photovoltaic systems protect the overload and short circuit protection of battery module strings, photovoltaic sub-arrays, photovoltaic arrays and photovoltaic inverters. PV series cylindrical cap photovoltaic fuse specificationsTypeRated Voltage(V)Rated Current(A)Dimension  (mm)Breaking capacity KAOutlineΦDLHPV-103810002、3、4、5、6、8、10、12、15、20、25、3010.33810.5≥20Fig.1PV-1451100010、12、15、20、25、32、4014.35113.8PV-108515002、3、4、5、6、8、10、12、15、20、25、3010.38510.5PV-1451150010、12、15、20、25、32、4014.35113.8PV-1465150010、12、15、20、25、32、40、50、6314.36513.8 Outline dimension:Fig.1 Fig.2
Model: PV
Type: Low Voltage Fuse
Applicable: Low Voltage
Colour:
Origin:
ZhenLi Nuobo
  • Parameter
  • Specification
  • Service

TypePV-□-□VDC/□A

DC fuse for solar PV system protection

Executive StandardIEC60269.6; GB/T13539.6

Rated VoltageDC 1000V1500V

Rated Current1A-400A

Breaking CapacitySee below table

Protection FeaturegPV

Installation modeRound tube with base; Square tube insert type

CharacteristicFull range DC breaking fuse, time constant T≤3ms.

Suitable forSolar photovoltaic systems protect the overload and short circuit protection of battery module strings, photovoltaic sub-arrays, photovoltaic arrays and photovoltaic inverters.

 

PV series cylindrical cap photovoltaic fuse specifications

Type

Rated VoltageV

Rated

CurrentA

Dimension  (mm)

Breaking capacity KA

Outline

ΦD

L

H

PV-1038

1000

234568101215202530

10.3

38

10.5

20

Fig.1

PV-1451

1000

10121520253240

14.3

51

13.8

PV-1085

1500

234568101215202530

10.3

85

10.5

PV-1451

1500

10121520253240

14.3

51

13.8

PV-1465

1500

101215202532405063

14.3

65

13.8

 

Outline dimension

DC fuse for solar PV system protection

Fig.1

DC fuse for solar PV system protection

 Fig.2


Overall installation dimension:


DC fuse for solar PV system protection



DC fuse for solar PV system protection

PV

Hot Products / Hot Products More
2018 - 08 - 30
Type:EV17-□-□VDC/□APerformance coincidence:IEC60269;GB/T31465 ;JASO D622Rated voltage: AC 250V,690V;DC 150V,500V,750VRated current:10A-500ABreaking capacity:AC:100KA; DC:20KAProtective Type:aRInstallation mode:Bolted connectionCharacteristic:Small size, low power consumption, high breaking ability, time constant T Suitable for:Short circuit protection for large, medium and small passenger cars, pa...
Copyright © 2005 - 2013 ShaanXi ZhenLi Electric Power Technology Co.,Ltd.
犀牛云提供企业云服务    
   
Sweep the concern our letter
Address:No.2055,Shanglinyuan 5th Road, High-tech district, Xi'an City Shaanxi Province, China 
Tel: 86 029-86795471
Fax: 86 029-86307131
Zip Code:330520
Share to:
X
等待加载动态数据...

等待加载动态数据...

3

SKYPE 设置

4

阿里旺旺设置

5

TEL:

6

二维码管理

展开